Mitsubishi FX3G Series Programming Manual page 925

Programmable controllers
Hide thumbs Also See for FX3G Series:
Table of Contents

Advertisement

FX
/FX
/FX
/FX
3G
3U
3GC
3UC
Programming Manual - Basic & Applied Instruction Edition
• FX
/FX
PLCs (Extension mode)
3G
3GC
Applied instruction
MOV instruction (FNC 12)
BCD instruction (FNC 18)
BIN instruction (FNC 19)
ADD instruction (FNC 20)
SUB instruction (FNC 21)
MUL instruction (FNC 22)
DIV instruction (FNC 23)
INC instruction (FNC 24)
DEC instruction (FNC 25)
WAND instruction (FNC 26)
WOR instruction (FNC 27)
WXOR instruction (FNC 28)
Other applied instructions
Series
B-5 Execution Time of Pulse Generation Instruction P in Each Applied Instruction
Execution time at rising edge of input: Execution time in ON status = 5.43 µs
Non-execution time: Execution time in OFF status = 0.81 µs
Execution time at rising edge of input: Execution time in ON status = 5.42 µs
Non-execution time: Execution time in OFF status = 0.81 µs
Execution time at rising edge of input: Execution time in ON status = 5.21 µs
Non-execution time: Execution time in OFF status = 0.81 µs
Execution time at rising edge of input: Execution time in ON status = 6.68 µs
Non-execution time: Execution time in OFF status = 0.81 µs
Execution time at rising edge of input: Execution time in ON status = 6.78 µs
Non-execution time: Execution time in OFF status = 0.81 µs
Execution time at rising edge of input: Execution time in ON status = 7.24 µs
Non-execution time: Execution time in OFF status = 0.81 µs
Execution time at rising edge of input: Execution time in ON status = 7.44 µs
Non-execution time: Execution time in OFF status = 0.81 µs
Execution time at rising edge of input: Execution time in ON status = 3.49 µs
Non-execution time: Execution time in OFF status = 0.81 µs
Execution time at rising edge of input: Execution time in ON status = 3.49 µs
Non-execution time: Execution time in OFF status = 0.81 µs
Execution time at rising edge of input: Execution time in ON status = 6.81 µs
Non-execution time: Execution time in OFF status = 0.81 µs
Execution time at rising edge of input: Execution time in ON status = 6.81 µs
Non-execution time: Execution time in OFF status = 0.81 µs
Execution time at rising edge of input: Execution time in ON status = 6.81 µs
Non-execution time: Execution time in OFF status = 0.81 µs
Execution time at rising edge of input: Execution time in ON status + 0.7 µs
Non-execution time: Execution time in OFF status + 0.6 µs
Execution time
B Instruction Execution Time
Remarks
923
31
32
33
34
35
36
37
38
A
B