Mitsubishi FX3G Series Programming Manual page 830

Programmable controllers
Hide thumbs Also See for FX3G Series:
Table of Contents

Advertisement

FX
/FX
/FX
/FX
3G
3U
3GC
3UC
Programming Manual - Basic & Applied Instruction Edition
Number and name
Positioning [FX
PLC] (Refer to Positioning Control Manual for details.)
3U
[Y003] Pulse output monitor (ON: BUSY/ OFF:
[M]8370
READY)
*1
[Y003] Clear signal output function enable
M 8371
*1
[Y003] Zero return direction specification
M 8372
M 8373
[Y003] Forward limit
M 8374
[Y003] Reverse limit
*1
[Y003] DOG signal logic reverse
M 8375
*1
[Y003] Zero point signal logic reverse
M 8376
*1
[Y003] Interrupt signal logic reverse
M 8377
[M]8378
[Y003] Positioning instruction activation
*1
[Y003] Pulse output stop command
M 8379
RS2 (FNC 87) [ch0] [FX
, FX
3G
[M]8370
Not used
*1
RS2 (FNC 87) [ch0] instruction: Send wait flag
[M]8371
*1
RS2 (FNC 87) [ch0] instruction: Send request
M 8372
RS2 (FNC 87) [ch0] instruction: Receive
*1
M 8373
complete flag
[M] 8374 to [M] 8378
Not used
RS2 (FNC 87) [ch0] instruction: Time-out check
M 8379
flag
*1.
These devices are cleared when the PLC mode switches from RUN to STOP or when the RS2 instruction
[ch0] turns OFF.
*2.
Available only when two FX
High-Speed Counter Function (Refer to Subsection 4.7.5 and 4.7.6 for details.)
Operation status of C235, C241, C244, C246,
*3
[M]8380
C247, C249, C251, C252, and C254
*3
Operation status of C236
[M]8381
*3
Operation status of C237, C242, and C245
[M]8382
Operation status of C238, C248, C248 (OP),
*3
[M]8383
C250, C253, and C255
*3
Operation status of C239 and C243
[M]8384
*3
Operation status of C240
[M]8385
*3
Operation status of C244 (OP)
[M]8386
*3
Operation status of C245 (OP)
[M]8387
[M]8388
Contact for high-speed counter function change
M 8389
External reset input logic reverse
M 8390
Function changeover device for C244
M 8391
Function changeover device for C245
Function changeover device for C248 and
M 8392
C253
*3.
Cleared when PLC switches from STOP to RUN.
Interrupt Program
[M]8393
Contact for delay time setting
HCMOV (FNC189): Drive contact for interrupt
[M]8394
program
[M]8395
Function changeover device for C254
[M]8396
Not used
[M]8397
Ring Counter
Ring counter operation (in units of 1ms, 32
M 8398
*4
bits)
[M]8399
Not used
*4.
1ms ring counter (D8399, D8398) will operate after M8398 turns ON.
828
Series
Operation and function
PLCs] (Refer to Data Communication Edition for details.)
3GC
-2HSY-ADP units are connected to an FX
3U
37 Operation of Special Devices (M8000 -, D8000 -)
37.1 Special Device List (M8000 -, D8000 -)
Applicable model
Correspond-
FX
FX
FX
FX
3G
3GC
3U
3UC
*2
*2
*2
*2
*2
*2
*2
*2
*2
*2
ing special
FX
FX
FX
FX
1S
1N
2N
device
D8372
D8373
PLC.
3U
D8393
D8398,
D8399
FX
1NC
2NC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u seriesFx3gc seriesFx3uc series