Frequency control mode (HSZ and PLSY instructions) (M8132)

When the special auxiliary relay M8132 for declaring the frequency control mode is specified as
instruction, the special function shown below is provided if DPLSY instruction is combined.
At this time, only a data register D can be specified as
available range is limited to "1 ≤ K, H ≤ 128".
A high-speed counter C235 to C255 can be specified as
This function is different from the zone comparison described above.
PLSY instruction is as shown on the next page, and only the pulse output can be changed by users.
1. Control example
Example of table configuration and data setting
Comparison data
D 301,D 300
K 20
D 305,D 304
K600
D 309,D 308
K700
D 313,D 312
K800
D 317,D 316
K 0
Series
Frequency
D 302, D 303
K300
D 306, D 307
K500
D 310, D 311
K200
D 314, D 315
K100
D 318, D 319
K 0
13 High-Speed Processing – FNC 50 to FNC 59
13.6 FNC 55 – HSZ / High-Speed Counter Zone Compare
S
, and a constant K or H can be specified as
1
S
.
Table counter D8131
0
1
2
3
4
D
in the DHSZ
S
. The
2
Head device (32 bits)
specified as S
1
Number of lines specified
as
S
2
361