Fnc 39 - Sfrd / Shift Read [Fifo Control] - Mitsubishi FX3G Series Programming Manual

Programmable controllers
Hide thumbs Also See for FX3G Series:
Table of Contents

Advertisement

FX
/FX
/FX
/FX
3G
3U
3GC
3UC
Programming Manual - Basic & Applied Instruction Edition
11.10 FNC 39 – SFRD / Shift Read [FIFO Control]
Outline
This instruction reads data for first-in first-out control.
1. Instruction format
FNC 39
P
SFRD
2. Set data
Operand Type
S
D
n
*1.
"+1" is required for the pointer.
3. Applicable devices
Bit Devices
Oper-
and
System User
Type
X Y M T C S D .b KnX KnY KnM KnS T
S
D
n
: This function is supported only in FX
Explanation of function and operation
1. 16-bit operation (SFRD and SFRDP)
+1 written in turn by SFWR (FNC 38) instruction is transferred (read) to
S
1
are shifted rightward by 1 word. "1" is subtracted from the number of data, stored in
Command
input
FNC 39
SFRDP
Series
Mnemonic
16-bit Instruction
SFRD
7 steps
SFRDP
Head word device number storing data
(The first word device works as the pointer, and data is stored in
Word device number storing data taken out first 2 ≤ n ≤ 512
*1
Number of store points plus "1"
Digit Specification
/FX
3U
3UC
S
D
n
11 Rotation and Shift Operation – FNC 30 to FNC 39
11.10 FNC 39 – SFRD / Shift Read [FIFO Control]
Operation Condition
32-bit Instruction
Continuous
Operation
Pulse (Single)
Operation
Description
S
2 ≤ n ≤ 512
Word Devices
Special
System User
Unit
C D R U \G
V
PLCs.
Mnemonic
Operation Condition
Data Type
16-bit binary
+1 and later.)
16-bit binary
16-bit binary
Others
Con-
Real
Charac-
Index
stant
Number
ter String
Z Modify K H
E
" "
, and "n-1" words from
D
.
S
11
12
13
14
15
Pointer
P
16
17
+1
S
1
18
19
20
307

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u seriesFx3gc seriesFx3uc series

Table of Contents