DeepMind 12 User Manual
SLEW-RATE - This option allows you to adjust the SLEW RATE of the CONTROL
SEQUENCER. The SLEW RATE is the rate at which the value changes from one step
to the next. With a high slew rate you will get a sloped transition between steps,
and with a SLEW RATE of 0, you will get an instantaneous change from one step
to the next.
CONTROL SEQUENCER SLEW RATE
0
85
170
255
The SLEW RATE range is from 0-255, with 0 being no change and 255 full
smoothing.
The default SLEW RATE setting is 0.
KEY/LOOP - The KEY/LOOP mode controls how the CONTROL SEQUENCER looping
and key synchronisation operate. The choices are as follows:
• •
Loop On - This option makes the CONTROL SEQUENCE loop continuously
but does not restart when keys are pressed. This mode is useful when using
the CONTROL SEQUENCER in conjunction with the ARPEGGIATOR and the
SEQUENCE LENGTH is longer than the ARPEGGIATOR CLOCK DIVIDER.
• •
Key Sync On - This option will force the SEQUENCE to restart when a key is
pressed. Note in this mode the CONTROL SEQUENCER will not loop.
Key&Loop On - This option makes the CONTROL SEQUENCE loop
• •
continuously and also forces a reset when keys are pressed.
SEQUENCE EDITING - To use the SEQUENCE EDITOR make sure that the ' < ' symbol
on the SEQUENCE line is highlighted. Then press the +/YES switch and the
SEQUENCE EDITOR will then be displayed:
The controls for the SEQUENCE EDITOR are as follows:
(1)
(2)
(3)
Note: The parameter being edited is selected using the switches directly under
the tabs at the bottom of the screen.
(1) TITLE - The top bar shows the text "SEQUENCE EDITOR".
(2) STEP INDICATORS - The STEP values are shown at the top of the screen. The
current step can be selected using the rotary knob, each click will move the
selection forward or backward one step. The current step number is
displayed in header and the step is highlighted in black and indicated using a
dotted rectangle.
Note: When the CONTROL SEQUENCER is ON and running, you will see a
SEQUENCE POSITION POINTER (SPP) under the step being played. The SPP is a
small black bar which is updated in real-time.
Note: To duplicate steps start by selecting the step to duplicate, hold the
PROG switch, then navigate to target step and release the PROG switch.
(3) VALUE - The VALUE of each step is shown by the height of the bar within the
step. To adjust the value for a step, press the PROG switch (under the VALUE
text) to enter VALUE editing mode. When you are in VALUE editing mode the
virtual switch will be reversed (white on black).
(4)
(5)
(6)