show alarm settings

show alarm settings
Use the show alarm settings user EXEC command to display all environmental alarm settings on the
switch.
Syntax Description
| begin
| exclude
| include
expression
Command Modes
User EXEC
Command History
Release
12.1(12c)EA1
Usage Guidelines
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output
do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show alarm settings command. It shows all the switch alarm
settings that are on the switch:
Switch> show alarm settings
Power Supply
Temperature-Primary
Temperature-Secondary
Catalyst 2950 and Catalyst 2955 Switch Command Reference
A-14
show alarm settings [ | {begin | exclude | include} expression]
(Optional) Display begins with the line that matches the expression.
(Optional) Display excludes lines that match the expression.
(Optional) Display includes lines that match the specified expression.
Expression in the output to use as a reference point.
Modification
This command was introduced.
Mode
Alarm
Relay
Notifies
Syslog
Alarm
Thresholds
Relay
Notifies
Syslog
Alarm
Threshold
Relay
Notifies
Syslog
Single
Disabled
MIN
Disabled
Disabled
Enabled
MAX: 95C
MAJ
Enabled
Enabled
Disabled
Disabled
Disabled
Appendix A
Catalyst 2955 Alarm Commands
MIN:
-20C
OL-10102-01