alarm facility temperature

alarm facility temperature
Use the alarm facility temperature global configuration command to configure a primary temperature
monitoring alarm or to configure a secondary temperature alarm threshold with a lower maximum
temperature threshold. Use the no form of this command to delete the temperature monitoring alarm
configuration or to disable the secondary temperature alarm.
Syntax Description
threshold
notifies
relay major
relay minor
syslog
Defaults
The primary temperature alarm is enabled for a -20 to 95
with a major relay. The secondary temperature alarm is disabled by default.
Command Modes
Global configuration
Command History
Release
12.1(12c)EA1
Usage Guidelines
The primary temperature alarm is automatically enabled. It cannot be disabled, but you can configure
alarm options.
You can use the secondary temperature alarm to trigger a high temperature alarm at lower than the
maximum primary temperature threshold (95
options.
Before you use the notifies keyword to sent alarm traps to an SNMP host, you need to set up an SNMP
server by using the snmp-server enable traps global configuration command.
Catalyst 2950 and Catalyst 2955 Switch Command Reference
A-4
alarm facility temperature {primary {notifies | relay {major | minor} | syslog} | secondary
{threshold | notifies | relay {major | minor}| syslog}}
no alarm facility temperature {primary {notifies | relay {major | minor} | syslog} | secondary
{threshold | notifies | relay {major | minor}| syslog}}
Set a lower high temperature threshold for the secondary temperature alarm in
degrees C. The allowable range is 40 to 95
Send primary or secondary temperature alarm traps to a Simple Network
Management Protocol (SNMP) server.
Send the primary or secondary temperature alarm to the major relay circuitry.
Send the primary or secondary temperature alarm to the minor relay circuitry.
Send primary or secondary temperature alarm traps to a syslog server.
Modification
This command was introduced.
Appendix A
o
C.
o
C range and cannot be deleted. It is associated
o
C). You can configure the temperature threshold and alarm
Catalyst 2955 Alarm Commands
OL-10102-01