Sensor Mounting; Wiring Diagram; Cleaning And Maintenance - Banner q4x Instruction Manual

Stainless steel laser sensor
Hide thumbs Also See for q4x:
Table of Contents

Advertisement

2.3 Sensor Mounting

1. If a bracket is needed, mount the sensor onto the bracket.
2. Mount the sensor (or the sensor and the bracket) to the machine or equipment at the desired location. Do not
tighten at this time.
3. Check the sensor alignment.
4. Tighten the screws to secure the sensor (or the sensor and the bracket) in the aligned position.

2.4 Wiring Diagram

1
3
2
Load
4
Load
5
NOTE: Open lead wires must be connected to a terminal block.
NOTE: The input wire function is user-selectable. The default for the input wire function is off
(disabled).

2.5 Cleaning and Maintenance

Handle the sensor with care during installation and operation. Sensor windows soiled by fingerprints, dust, water, oil, etc.
may create stray light that may degrade the peak performance of the sensor. Blow the window clear using filtered,
compressed air, then clean as necessary using water and a lint-free cloth.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
+
10-30V dc
Remote
Teach
Q4X Stainless Steel Laser Sensor
1
2
4
3
5
Key
1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray

Advertisement