Sync Master/Slave - Banner q4x Instruction Manual

Stainless steel laser sensor
Hide thumbs Also See for q4x:
Table of Contents

Advertisement

Method
Action
Push Button
Press and hold TEACH for longer than 2 seconds.
Remote Input No action required.
3. Teach the sensor.
Method
Action
Push Button
Press TEACH to teach the target.
Remote Input Single-pulse the remote input.
Table 5: Expected TEACH Behavior for One-Point Background Suppression
See
Figure 16
on page 23 for the minimum object separation.
Condition
One valid distance
One invalid TEACH point

3.7 Sync Master/Slave

Two Q4X sensors may be used together in a single sensing application. To eliminate crosstalk between the two sensors,
configure one sensor to be the master and one to be the slave. In this mode, the sensors alternate taking measurements
and the response speed doubles.
Important: The Master sensor and the Slave sensor must be programmed for the same Response
Speed and Gain mode settings. The Master sensor and Slave sensor must share a common power
source.
1. Configure the first sensor as the master; navigate:
2. Configure the second sensor as the slave; navigate:
3. Connect the gray (input) wires of the two sensors together.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
TEACH Result
Sets a switch point in front of the
taught distance by the vertical
minimum object separation.
Sets a switch point at 200 mm.
>
>
Q4X Stainless Steel Laser Sensor
Result
Light Operate
and
on the display. The BGS indicator
flashes.
Dark Operate
and
on the display. The BGS indicator
flashes.
N/A
Result
The new switch point flashes rapidly
T
and the sensor returns to Run mode.
Display
The switch point distance flashes on
the display.
and the switch point distance
flash alternately on the display.
.
.
flash alternately
flash alternately

Advertisement

Table of Contents
loading