Shift The Zero Reference Location After A Teach; Input Wire Function; Display View; Exit Setup Mode - Banner q4x Instruction Manual

Stainless steel laser sensor
Hide thumbs Also See for q4x:
Table of Contents

Advertisement

Q4X Stainless Steel Laser Sensor

3.2.5 Shift the Zero Reference Location after a TEACH

Use this menu to select whether the sensor shifts the zero reference location to the last taught distance. The default is
, 0 = the end of barrel or the maximum range.
—Shift the zero reference location to one of the taught positions with each TEACH
—0 = the end of barrel or the maximum range, depending on the

3.2.6 Input Wire Function

Use this menu to select the input wire function. The default is off, ignore all remote input pulses.
—Ignore all remote input pulses
—Remote TEACH input
—Laser off when pulled low
—Master sync line output for two-sensor cross-talk avoidance
—Slave sync line input for two-sensor cross-talk avoidance
To configure sensors for master-slave operation, see

3.2.7 Display View

Use this menu to select the display view. The default is right-reading.
—Right-reading
—Inverted
—Right-reading and the display enters sleep mode after 60 seconds
—Inverted and the display enters sleep mode after 60 seconds
When the sensor is in sleep mode, the display wakes with the first button press.

3.2.8 Exit Setup Mode

Navigate to
and press SELECT to exit Setup mode and return to Run mode.

3.2.9 Reset to Factory Defaults

Use this menu to restore the sensor to the factory default settings. See
Select
to return to the sensor menu without restoring the defaults. Select
return to Run mode.
Factory Default Settings
Setting
Display view (
)
Gain and sensitivity (
Input wire function (
Output configuration
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Sync Master/Slave
)
)
setting
on page 21.
Factory Default Settings
Factory Default
—Right-reading, no sleep mode
—High excess gain mode
—Ignore all remote input pulses
If the sensor was reset using the remote input, the sensor
remains in
mode to allow use of the remote input.
LO—Light Operate
on page 12.
to apply the factory defaults and

Advertisement

Table of Contents
loading

Table of Contents