Banner q4x Instruction Manual page 16

Stainless steel laser sensor
Hide thumbs Also See for q4x:
Table of Contents

Advertisement

Q4X Stainless Steel Laser Sensor
Press and Hold
> 2s
NOTE: The sensor must be set to
NOTE: To program the sensor using remote input, remote input must be enabled (
1. Present the target.
Method
Action
Push Button
Present the first target. The sensor-to-target distance must be within
the sensor's range.
Remote Input
2. Start the TEACH mode.
Method
Action
Push Button
Press and hold TEACH for longer than 2 seconds.
Remote Input No action required.
3. Teach the sensor.
Method
Action
Push Button
Press TEACH to teach the target.
Remote Input Single-pulse the remote input.
4. Present the target.
Method
Action
Push Button
Present the second target. The sensor-to-target distance must be
within the sensor's range.
Remote Input
5. Teach the sensor.
Method
Action
Push Button
Press TEACH to teach the target.
Remote Input Single-pulse the remote input.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
2
Press again
1
Figure 12. Two-Point Static Background Suppression (Light Operate shown)
=
3
Press again
to use the following instructions.
T
T
5
Switch
Point
Value
4
=
Result
The target's measurement value
displays.
Result
and
flash alternately
on the display. The DYN, FGS, and
BGS indicators flash.
N/A
Result
The sensor is taught the first target.
,
, and the current
distance measurement flash
alternately on the display. The DYN,
FGS, and BGS indicators flash.
Result
,
, and the distance
measurement flash alternately on the
display. The DYN, FGS, and BGS
indicators flash.
Result
The new switch point flashes rapidly
and the sensor returns to Run mode.
).

Advertisement

Table of Contents
loading

Table of Contents