Q4X Stainless Steel Laser Sensor

4 Specifications

Sensing Beam
Visible red Class 1 laser, 655 nm
Supply Voltage (Vcc)
10 to 30 V dc
Power and Current Consumption, exclusive of load
< 675 mW
Sensing Range
25 mm (0.98 in) to 300 mm (11.81 in)
Output Configuration
Bipolar (1 PNP & 1 NPN) output
Output Rating
Off-state leakage current: < 5 µA at 30 V dc
PNP On-state saturation voltage: < 1.5 V dc at 100 mA load
NPN On-state saturation voltage: < 1.0 V dc at 100 mA load
Remote Input
Allowable Input Voltage Range: 0 to Vcc
Active Low (internal weak pullup—sinking current): Low
State < 2.0 V at 1 mA max.
Supply Protection Circuitry
Protected against reverse polarity and transient over-voltages
Beam Spot Size
Table 6: Beam Spot Size
Distance (mm)
25
150
300
Temperature Effect
0.05 mm/°C at 125 mm
0.35 mm/°C at 300 mm
Excess Gain
Table 7:
Excess Gain (
Response
Excess Gain (90%
Speed (ms)
White Card at 25
mm)
1.5
3
10
1000 (500)
25
2500 (1000)
50
5000 (2500)
Connector
5-pin Euro M12 Integral Connector
Construction
Housing: 316 L stainless steel
Lens cover: PMMA acrylic
Lightpipe and display window: polysulfone
1
excess gain available in 10 ms, 25 ms, and 50 ms response speeds only
excess gain provides increased noise immunity
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Size (Horizontal × Vertical)
2.6 mm × 1.0 mm
2.3 mm × 0.9 mm
2.0 mm × 0.8 mm
Excess Gain 1 )
Excess Gain (90%
White Card at 300
mm)
200
20
200
20
100 (50)
250 (100)
500 (250)
Response Speed
User selectable:
—1.5 milliseconds
—3 milliseconds
—10 milliseconds
—25 milliseconds
—50 milliseconds
Delay at Power Up
< 750 ms
Ambient Light Immunity
> 5,000 lux
Maximum Torque
Side mounting: 1 N·m (9 in·lbs)
Nose mounting: 20 N·m (177 in·lbs)
Vibration
MIL-STD-202G, Method 201A (10 to 60 Hz, 0.06 in (1.52
mm) double amplitude, 2 hours each along X, Y and Z
axes), with sensor operating
Shock
MIL-STD-202G, Method 213B, Condition I (100G 6x along X,
Y and Z axes, 18 total shocks), with sensor operating
Environmental Rating
IEC IP67 per IEC60529
IEC IP68 per IEC60529
IEC IP69K per DIN40050-9
Chemical Compatibility
Compatible with commonly used acidic or caustic cleaning
and disinfecting chemicals used in equipment cleaning and
sanitation.
Compatible with typical cutting fluids and lubricating fluids
used in machining centers
Operating Conditions
−10 °C to +50 °C (+14 °F to +122 °F)
35% to 95% relative humidity
Storage Temperature
–25 °C to +75 °C (−13 °F to +167 °F)
Application Note
For optimum performance, allow 10 minutes for the sensor
to warm up
Certifications
UL Environmental Rating: Type 1
Class 2 Power supply/source to be
Class 2 power
provided with 1A overcurrent
Ind. Cont. Eq.
protection device. Power supply could
3TJJ
be current limiting or an 1A external
fuse is required on the power output.
®