Banner q4x Instruction Manual page 19

Stainless steel laser sensor
Hide thumbs Also See for q4x:
Table of Contents

Advertisement

Press and Hold
> 2s
NOTE: The sensor must be set to
is amber to indicate One-Point Window (Foreground Suppression) mode.
NOTE: To program the sensor using remote input, remote input must be enabled (
1. Present the target.
Method
Action
Push Button
Present the target. The sensor-to-target distance must be within the
sensor's range.
Remote Input
2. Start the TEACH mode.
Method
Action
Push Button
Press and hold TEACH for longer than 2 seconds.
Remote Input No action required.
3. Teach the sensor.
Method
Action
Push Button
Press TEACH to teach the target.
Remote Input Single-pulse the remote input.
Table 4: Expected TEACH Behavior for One-Point Window (Foreground Suppression)
See
Figure 16
on page 23 for the minimum object separation.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
2
Press again
1
Figure 14. One-Point Window (Foreground Suppression)
3
=
to use the following instructions. The FGS indicator
T
Q4X Stainless Steel Laser Sensor
Switch
Point
Value A
Switch
Point
Value -A
=
).
Result
The target's measurement value
displays.
Result
Light Operate
and
flash alternately
on the display. The FGS indicator
flashes.
Dark Operate
and
flash alternately
on the display. The FGS indicator
flashes.
N/A
Result
The ± window size flashes rapidly
and the sensor returns to Run mode.