Connecting Network Cables to SRX5600 Services Gateway IOCs and Port Modules
68
The terminal blocks that plug into the alarm relay contacts are supplied with the services
gateway. They accept wire of any gauge between 28-AWG and 14-AWG (0.08 and
2
2.08 mm
), which is not provided. Use the gauge of wire appropriate for the external
device you are connecting.
To connect an external device to an alarm relay contact (see Figure 31 on page 68):
Prepare the required length of wire with gauge between 28-AWG and 14-AWG (0.08
1.
2
and 2.08 mm
).
While the terminal block is not plugged into the relay contact, use a 2.5-mm flat-blade
2.
screwdriver to loosen the small screws on its side. With the small screws on its side
facing left, insert wires into the slots in the front of the block based on the wiring for
the external device. Tighten the screws to secure the wire.
Plug the terminal block into the relay contact, and use a 2.5-mm flat-blade screwdriver
3.
to tighten the screws on the face of the block.
Attach the other end of the wires to the external device.
4.
To attach a reporting device for the other kind of alarm, repeat the procedure.
Figure 31: Alarm Relay Contacts
Tools and Parts Required for SRX5600 Services Gateway Connections on page 65
Overview of Installing the SRX5600 Services Gateway on page 43
Alarm Relay Contact Wire Specifications for the SRX5600 Services Gateway on page 226
Connecting the SRX5600 Services Gateway to a Network for Out-of-Band Management
on page 66
Connecting the SRX5600 Services Gateway to a Management Console or an Auxiliary
Device on page 67
Connecting Network Cables to SRX5600 Services Gateway IOCs and Port Modules
on page 68
To connect the IOCs or port modules to the network (see Figure 32 on page 69):
Have ready a length of the type of cable used by the component.
1.
Remove the rubber safety plug from the cable connector port.
2.