Srx5600 Services Gateway Ac Power Supply Leds; Srx5600 Services Gateway Dc Power Configurations; Srx5600 Services Gateway Dc Power Supply; Srx5600 Services Gateway Dc Power Supply Leds - Juniper SRX5600 Hardware Manual

Services gateway
Hide thumbs Also See for SRX5600:
Table of Contents

Advertisement

SRX5600 Services Gateway Power System Overview
Related
Documentation
SRX5600 Services Gateway AC Power Configurations
Copyright © 2010, Juniper Networks, Inc.
SRX5600 Services Gateway AC Power Supply LEDs on page 35
SRX5600 Services Gateway DC Power Configurations on page 35
SRX5600 Services Gateway DC Power Supply on page 36
SRX5600 Services Gateway DC Power Supply LEDs on page 37
The services gateway uses either AC or DC power supplies. The services gateway is
configurable with two, three, or four AC power supplies or two or four DC power supplies.
The power supplies connect to the midplane, which distributes the different output
voltages produced by the power supplies to the services gateway components, depending
on their voltage requirements. Each power supply is cooled by its own internal cooling
system.
CAUTION: The services gateway cannot be powered from AC and DC power
supplies simultaneously. The first type of power supply detected by the
services gateway when initially powered on determines the type of power
supply allowed by the services gateway. All installed power supplies of the
other type are disabled by the services gateway. If you install a power supply
of the other type while the services gateway is operating, the services gateway
disables the power supply and generates an alarm.
Redundant power supplies are hot-removable and hot-insertable. When you remove a
power supply from a services gateway that uses a nonredundant power supply
configuration, the services gateway may shut down depending on your configuration.
SRX5600 Services Gateway AC Power Configurations on page 33
SRX5600 Services Gateway AC Power Supply on page 34
SRX5600 Services Gateway AC Power Supply LEDs on page 35
SRX5600 Services Gateway DC Power Configurations on page 35
SRX5600 Services Gateway DC Power Supply on page 36
SRX5600 Services Gateway DC Power Supply LEDs on page 37
Troubleshooting the SRX5600 Services Gateway Power System on page 113
The services gateway supports either the low-line (110V) AC power configuration or the
high-line (220V) AC power configuration.
In the low-line (110 V) AC power configuration, the services gateway contains three or
four AC power supplies, located horizontally at the rear of the chassis in slots
through
(left to right). Each AC power supply provides power to all components
PEM3
in the services gateway. When three power supplies are present, they share power
almost equally within a fully populated system. Four AC power supplies provide full
power redundancy. If one power supply fails or is removed, the remaining power supplies
Chapter 2: SRX5600 Services Gateway Hardware Components