NOTE:
In North America, AC power cords must not exceed 4.5 m
(approximately 14.75 ft) in length, to comply with National Electrical code
(NEC) Section 400-8 (NFPA 75, 5-2.2) and 210-52, and Canadian Electrical
Code (CEC) Section 4-010(3).
Table 15 on page 51
provides power cord specifications, and
the plug on the AC power cord provided for each country or region.

Table 15: AC Power Cord Specifications

Country
Australia
China
Europe (except Italy and United Kingdom)
Italy
Japan
North America
United Kingdom

Figure 13: AC Plug Types

NOTE:
Power cords and cables must not block access to services gateway
components or drape where people might trip on them.
SRX550 Services Gateway Power Supply on page 29
Clearance Requirements for Airflow and Hardware Maintenance of the SRX550 Services
Gateway on page 44
SRX550 Services Gateway Electrical Wiring Guidelines on page 49
Site Preparation Checklist for the SRX550 Services Gateway on page 35
Chapter 10: Power Requirements and Specifications
Figure 13 on page 51
Electrical Specification
250 VAC, 10 A, 50 Hz
250 VAC, 10 A, 50 Hz
250 VAC, 10 A, 50 Hz
250 VAC, 10 A, 50 Hz
125 VAC, 12 A, 50 or 60 Hz
125 VAC, 10 A, 60 Hz
250 VAC, 10 A, 50 Hz
depicts
Plug Standards
AS/NZ 3112-1993
GB2099.1 1996 and
GB 1002 1996
(CH1-10P)
CEE (7) VII
CEI 23-16/VII
JIS 8303
NEMA 5-15
BS 1363A
51