CHAPTER 10

Power Requirements and Specifications

SRX550 Services Gateway Electrical Wiring Guidelines

Copyright © 2015, Juniper Networks, Inc.
SRX550 Services Gateway Electrical Wiring Guidelines on page 49
SRX550 Services Gateway Supported AC Power Cords on page 50
SRX550 Services Gateway AC Power Supply Electrical Specifications on page 52
SRX550 Services Gateway DC Power Cable Specifications on page 52
SRX550 Services Gateway DC Power Supply Electrical Specifications on page 53
SRX550 Services Gateway Power Requirements on page 54
Table 14 on page 49
describes the factors you must consider while planning the electrical
wiring for the SRX550 Services Gateway at your site.
CAUTION:
It is particularly important to provide a properly grounded and
shielded environment and to use electrical surge-suppression devices.
Table 14: Site Electrical Wiring Guidelines for the SRX550 Services
Gateway
Site Wiring Factor
Guideline
Signaling limitations
To ensure that signaling functions optimally:
Install wires correctly.
Improperly installed wires can emit radio interference.
Do not exceed the recommended distances or pass wires between
buildings.
The potential for damage from lightning strikes increases if wires exceed
recommended distances or if wires pass between buildings.
Shield all conductors.
The electromagnetic pulse (EMP) caused by lightning can damage
unshielded conductors and destroy electronic devices.
49