SRX550 Services Gateway Environmental Specifications

Related
Documentation
38
Table 12 on page 38
provides the required environmental conditions for normal SRX550
Services Gateway operations. In addition, the site must be as dust-free as possible
because dust can clog air intake vents, reducing the efficiency of the cooling system.

Table 12: SRX550 Services Gateway Environmental Specifications

Description
Altitude
Relative humidity
Temperature
Seismic
Maximum thermal output
NOTE:
Install the services gateway only in restricted areas, such as dedicated
equipment rooms and equipment closets, in accordance with Articles 110–16,
110–17, and 110–18 of the National Electrical Code, ANSI/NFPA 70.
SRX550 Services Gateway General Safety Guidelines and Warnings on page 163
Routine Maintenance Procedures for the SRX550 Services Gateway on page 125
Value
No performance degradation to 13,000 ft (3962.4 m)
Normal operation ensured in relative humidity range of 5%
to 90%, noncondensing
Normal operation ensured in temperature range of 32°F
(0°C) to 104°F (40°C)
Nonoperating storage temperature in shipping container:
–40°F (–40°C) to 158°F (70°C)
Designed to meet Telcordia Technologies Zone 4 earthquake
requirements
AC power: 4400 BTU/hour
DC power with one 645 W power supply unit: 2200 BTU/hour
DC power with two 645 W power supply units, nonredundant:
4400 BTU/hour
NOTE:
These specifications are estimates and subject to
change.