Position Control Parameter - Delta VFD-V Series User Manual

Flux vector control ac motor drivers
Table of Contents

Advertisement

VFD-V Series
This parameter is used to define the encoder input type on channel 2 of the PG04/05.

♦ Position Control Parameter

10-13
Proportional (P) Gain
Settings
10-14
Integral (I) Time
Settings
10-15
Differential (D) Time
Settings
10-16
Orient Speed
Settings
10-17
Creep point
Settings
Phase A is a forward run pulse, then phase B is High.
Phase B is a reverse run pulse, then phase A is High.
FWD
2
A
B
Phase B is a forward run pulse, then phase A is High.
Phase A is a reverse run pulse, then phase B is High.
FWD
3
A
B
Phase A is a pulse input, phase B is a direction input,
(low = reverse , high = forward)
FWD
4
A
B
Phase A is a pulse input, phase B is direction input.
(low = forward, high = reverse)
FWD
5
A
B
0.0~500.0%
0.000~100.000 Sec
0.000: no integral
0.00~1.00 Sec
0.00~400.00 Hz
0~20000
5-78
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
REV
REV
REV
REV
Factory setting
50.0
Factory setting
0.050
Factory setting
0.25
Factory setting
5.00
Factory setting
100