Process Control Operation Mode; Multi-Step Speed Operation Mode - Delta VFD-V Series User Manual

Flux vector control ac motor drivers
Table of Contents

Advertisement

04-33

Process Control Operation Mode

Bit setting
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Note: Please refer to Pr.02-01 to 02-06 and setting 23 "PCO time extension".
04-34

Multi-Step Speed Operation Mode

Bit 0
Bit setting
Bit 1
Bit 2
Program operation
command
Program operation
indication
Step operation
indication
Program operation
fulfillment indication
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
0 direction determined by Pr. 04-32
1 direction determined by the master speed control
0 continuously execute the process control operation
1 execute only one process control operation cycle
0 zero speed intervals disabled
1 zero speed intervals enabled
0 operate at zero speed upon time extension (note 1)
1 operate at a constant speed upon time extension (note 1)
0 PCO disabled
1 PCO enabled
0 direction determined by Pr. 04-32
1 direction determined by the master speed control
0 continuously execute multi-step speed
execute multi-step speed based on time (Pr. 4-15 to
1
4-30)
0 zero speed intervals disabled
1 zero speed intervals enabled
5-39
VFD-V Series
Factory setting
00000
0
2
1
2
2
2
3
2
4
2
Factory setting
00001
0
2
1
2
2
2
1
2
4
8
16
5
1
2
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents