Edma Channel Interrupt Pending Low Register (Ciprl); Edma Channel Interrupt Pending Registers (Ciprl, Ciprh) - Texas Instruments TMS320C6000 DSP Reference Manual

Enhanced direct memory access (edma) controller
Hide thumbs Also See for TMS320C6000 DSP:
Table of Contents

Advertisement

3.8.3

EDMA Channel Interrupt Pending Registers (CIPRL, CIPRH)

3.8.3.1

EDMA Channel Interrupt Pending Low Register (CIPRL)

Figure 3−8. EDMA Channel Interrupt Pending Low Register (CIPRL)
31
30
CIP31
CIP30
R/W-0
R/W-0
23
22
CIP23
CIP22
R/W-0
R/W-0
15
14
CIP15
CIP14
R/W-0
R/W-0
7
6
CIP7
CIP6
R/W-0
R/W-0
Legend: R/W = Read/Write; -n = value after reset
Table 3−9. EDMA Channel Interrupt Pending Low Register (CIPRL) Field Descriptions
Bit
Field
symval
31−0
CIP
OF(value)
For CSL implementation, use the notation EDMA_CIPRL_CIP_symval.
SPRU234
The EDMA channel interrupt pending registers (CIPRL and CIPRH) are shown
in Figure 3−8 and Figure 3−9 and described in Table 3−9 and Table 3−10.
29
28
CIP29
CIP28
R/W-0
R/W-0
21
20
CIP21
CIP20
R/W-0
R/W-0
13
12
CIP13
CIP12
R/W-0
R/W-0
5
4
CIP5
CIP4
R/W-0
R/W-0
Value
Description
0−FFFF FFFFh Channel 0−31 interrupt pending bits. When the TCINT bit in
the channel options parameter (OPT) is set to 1 for an
EDMA channel and a specific transfer complete code (TCC)
is provided, the EDMA controller sets a bit in the CIP field.
27
26
CIP27
CIP26
R/W-0
R/W-0
19
18
CIP19
CIP18
R/W-0
R/W-0
11
10
CIP11
CIP10
R/W-0
R/W-0
3
2
CIP3
CIP2
R/W-0
R/W-0
TMS320C64x EDMA
EDMA Control Registers
25
24
CIP25
CIP24
R/W-0
R/W-0
17
16
CIP17
CIP16
R/W-0
R/W-0
9
8
CIP9
CIP8
R/W-0
R/W-0
1
0
CIP1
CIP0
R/W-0
R/W-0
3-17

Advertisement

Table of Contents
loading

Table of Contents