Konftel 300IP Manual page 33

Detailed end point ivt test plan and report
Hide thumbs Also See for 300IP:
Table of Contents

Advertisement

Test Case #
Objective
Pre-Test Conditions
Local CUCMDUT(s):7100 & 7101; SCCP:1000; SIP:2000;
Remote CUCM DUT:8000;
PSTN DN: 210-222-5400;
Enable Barge feature by setting Cluster-wide Service Parameters:
DevicePhoneDN:
Shared line DN:1901 added to devices with DN:7100, 7101,1000, & 2000;
Privacy on Phones with shared linesOff
Single Button BargecBarge
RPC is used to remotely control IP Phones with DN: 1000, 2000, 2102225400;
Test Procedure
1. 8000 dials 444-19011901 answers (Shared line on 7100)
2. 7101 selects line 1901 after 20s
3.1901 goes on-hook after 60s (Shared line on 7100)
4. 8000 goes on-hook after 80s
5. 2102225400 dials 941044419011901 answers (Shared line on 1000)
6. 2000 selects line 1901 after 20s
7. 7100 selects line 1901 Select 1901 after 30s
8. 1901 goes on-hook after 60s (Shared line on 7100)
9. Remaining 3 parties go-hook after 120s
10. Retrieve CDR from CUCM
11. Check the Calling, Called, Duration, Origination & Termination
Cause Codes
© 2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public.
EP-23
Category
Verify "cBarge" call using DUT(s), SCCP, SIP and PSTN endpoints
Built In Bridge EnableOn
Party Entrance ToneTrue
Test Results: Comments
cBarge not supported
Functional Test: cBarge
Expected Results
RFC_Standard
Call establish between 8000 & 1901 with 2-way audio
All 3 parties conference-in with 3-way audio
cBarge conference terminate normally
Call between 2102225400 & 1901 with 2-way audio
All 4 parties conference-in with 4-way audio
st
7100 terminated conference 1
3 parties terminate cBarge conference after 120s
11 CDR(s) retrieved
Selected fields in CDR match calls
P
F
N/A
N
N/S
N/T
B
x
Page 33 of 64