HP 5920 Configuration Manual page 285

Table of Contents

Advertisement

Operation
Description
Determines the action to take in
case of a configuration error.
The error-option element has
one of the following values:
edit-config:
error-option
stop-on-error—Stops the
operation on error and
returns an error message.
This is the default
error-option value.
continue-on-error—Continu
es the operation on error
and returns an error
message.
rollback-on-error—Rolls
back the configuration. This
value is not supported by the
current software version, and
it is reserved for future use.
275
XML example
To issue the configuration for two interfaces with the
error-option element value as continue-on-error:
<rpc message-id ="101"
xmlns="urn:ietf:params:xml:ns:netconf:ba
se:1.0">
<edit-config>
<target>
<running/>
</target>
<error-option>continue-on-error</error-o
ption>
<config
xmlns:xc="urn:ietf:params:xml:ns:netconf
:base:1.0">
<top
xmlns="http://www.hp.com/netconf/config:
1.0">
<Ifmgr xc:operation="merge">
<Interfaces>
<Interface>
<Index>262</Index>
<Description>222</Description>
<ConfigSpeed>100</ConfigSpeed>
<ConfigDuplex>1</ConfigDuplex>
</Interface>
<Interface>
<Index>263</Index>
<Description>333</Description>
<ConfigSpeed>100</ConfigSpeed>
<ConfigDuplex>1</ConfigDuplex>
</Interface>
</Interfaces>
</Ifmgr>
</top>
</config>
</edit-config>
</rpc>

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

5900

Table of Contents