PALACE™ SERIES OPTIONS
THE KENSINGTON, WESTMINSTER & BALMORAL FRONT
1) Remove fan cover by undoing screw.
2) Disconnect fan switch wires and discard fan cover with wires.
Discard Fan
Cover with Wires
3) Connect new fan control box wires to the existing fan plug wires (red
to red, black to black).
New Fan
Control Box
64
OPTIONAL FAN INSTALLATION
Fan Cover
Disconnect
Wires
4) Tuck wires in new fan control box and secure with screw.
Secure with screw.
5) Place fan control box under left side of fi rebox and secure to left side
vertical hinge bracket supplied screw.
Vertical Hinge
Bracket
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace
Fan Control Box
Fan Control Box