Venting Arrangements Vertical Termination - FPI P36D-NG1 Owners & Installation Manual

Direct vent gas fireplace
Hide thumbs Also See for P36D-NG1:
Table of Contents

Advertisement

INSTALLATION
The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90
rigid pipe vent systems for Propane and Natural Gas.
Vent must be supported at offsets.
Firestops are required at each fl oor level and whenever passing through a wall.
Maintain clearances to combustibles.
Note: Must use optional rigid pipe adaptor when using rigid vent systems (Part # 510-994).
26
VENTING ARRANGEMENTS
VERTICAL TERMINATION
RIGID PIPE SYSTEM