OPTIONAL FAN
INSTALLATION
120 Volt AC power is needed for the fan switch
and blower. The fan can be hard wired if desired.
The receptacle box should be installed on the left
hand side of the unit by a qualifi ed electrician. The
neutral (wider) slot of the polarized receptacle
should be at the top.
Unit must be grounded at all times. Do
not cut the ground terminal off under any
circumstances.
1) Shut the power off.
2) Remove the standard fl ush door and the
optional bay door, if installed. Open the
bottom louver door.
3) Loosen the 2 screws holding the Burner
ON/OFF switch and bracket to the bottom
louver and lift the assembly out.
4) Turn the fan base on its side (with the base
facing towards you) and then slide the fan
in towards the rear of the unit. Turn the fan
upright and slip it over the two mounting
studs. Take care not to damage the insulation
on the fan base. Ensure that the fan blades
do not rub against the valve tubing.
Diagram 1.
Diagram 1
5) Connect fan ground cable to ground lug.
Refer to wiring diagram.
48
6) Slide the thermodisc/cover assembly into
the bracket clip on the underside of the
fi rebox. Check that no wire will touch the
hot surfaces. Diagram 2.
Diagram 2
7) Attach the Fan control box to the Burner
ON/OFF control box.
Use the clip & hook on the side of the control
boxes to join them together.
8) Secure the two boxes together with one
screw.
Secure the 2 boxes together
with one screw.
9) Position the control box assembly on the
bottom louver and mark the position of the slot
on the right side bracket.
Hold control box assembly in place and mark
the position of the right side slot
10) Remove the control box assembly and push
the hold-down clip onto the louver. Bend the
tab until it is at 90
o
to the louver.
INSTALLATION
11) Attach the two control boxes to the bottom
louver and tighten the 2 screws on the left
side and 1 screw on the right side.
Secure left
side with 2
screws.
Secure right side with one screw.
12) Secure the fan wires and power cord by
attaching one of the adhesive backed wire
holder clips (Part #910-199) onto the stove
base. Use the second clip to bundle up the
wires approximately 4" from the control box.
Ensure that there is no interference with the
wires when the louver is closed and that
no wire will touch the hot metal surfaces or
sharp edges.
13) Plug the fan power cord into the rear end of
the receptacle box to provide the maximum
clearance from the louvers.

OPTIONAL FAN REMOVAL

1) Shut the power off.
2) Reverse the above instructions.
Note: The bearings are lubricated for life. Do
not lubricate them. Make sure you vacuum
the fan area on a regular basis.
IMPORTANT:
These fans collect a lot of dust from within
your home. Ensure you maintain these fan
motors on a regular basis by vacuuming
out the fan blades and housing using a soft
brush nozzle.
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace