INSTALLATION
The minimum components required for a basic
horizontal termination are:
1
Horizontal Termination Cap
1
90
o
Elbow
1
Rigid Pipe Adaptor
1
Wall Thimble
1
Length of pipe to suit wall thickness
(see chart)
Wall thickness is measured from the back standoffs
to the inside mounting surface of termination cap.
For siding other than vinyl furring strips may be used,
instead of the vinyl siding standoff, to create a level
surface to mount the vent terminal. The Terminal
must not be recessed into siding. Measure the wall
thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used
with vinyl siding), measure to outside surface of wall
without siding and add 2 inches.
Vertical
Termination
Cap
Storm Collar
Flashing
Ceiling Firestop
Pipe Length
The FPI AstroCap
TM
and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent
American Metal Products, Security Secure Vent
Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.
24

RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations

Wall Thickness (inches)
Wall Thickness (inches)
Vinyl Siding
Standoff (Optional)
Wall Thimble
Adj.Pipe Length
11" - 14-5/8"
o
90 Elbow
24" Pipe
Length
Rigid Pipe Adaptor
®
, AmeriVent Direct Vent. AstroCap
Flat Wall Installation
4" - 5-1/2"
7" - 8-1/2"
10" - 11-1/2"
9" - 14-1/2"
15" - 23-1/2"
Corner Installation
3-1/4" - 6-3/4"
7-3/4" - 16-1/4"
7-1/4" - 8-3/4"
4-1/4" - 5-3/4"
Horizontal
Termination
Cap
WARNING:
Do not combine venting components from
different venting systems.
However use of the AstroCap
is acceptable with all systems.
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with DuraVent Direct Vent GS, Selkirk Direct-
Temp, Ameri Vent Direct venting and Security
Secure Vent systems. Use of these systems with
the Rigid Pipe Adaptor is deemed acceptable
and does not affect the Intertek WHI listing of
components.
TM
is the proprietary trademark of FPI Fireplace Products International
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace
Vent Length Required (inches)
6"
9"
12"
11" - 14-5/8" Adj. Pipe
17" - 24" Adj. Pipe
Vent Length Required (inches)
11" - 14-5/8" Adj. Pipe
17" - 24" Adj. Pipe
6" + 12"
9" + 9"
6" + 9"
Alternate
Horizontal
Termination
Caps
TM
and FPI Riser
®
Direct Vent GS,