Wiring Diagrams - FPI P36D-NG1 Owners & Installation Manual

Direct vent gas fireplace
Hide thumbs Also See for P36D-NG1:
Table of Contents

Advertisement

This heater does not require a 120V A.C. sup-
ply for operation. In case of a power failure, the
burner switch and the optional remote control/
thermostat will continue to operate. However,
a 120V A.C. power supply is needed for the
fan/blower operation.
NATURAL GAS
For
Nut
Star washer
#8 Ground Lug
(for mobile home)
Lockwasher
Fan
ground wire
White
Burner ON
OFF
Red
Thermostat
Black
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace

WIRING DIAGRAMS

(Do not cut the ground terminal off under
any circumstances.)
Units and Units
Pilot
Assembly
Piezo
Ignitor
(To THTP)
(To TH)
T-Stat
ON OFF
Remote Receiver
or Thermostat
(Millivolt) (Optional)
CAUTION: Label all wires prior
to disconnection when servic-
ing controls. Wiring errors can
cause improper and dangerous
NOTE:
NOT
Equipped with DC Spark Boxes
Ground
Neutral
Live
Ground
120V AC
60 Hz
ON
Rotary Speed
Control
Brown
White
To Thermocouple IN
"S.I.T" Valve
Remote Transmitter
(Optional)
INSTALLATION
Even if the fan is not purchased
with the unit, it is still a good idea
to bring power to the receptacle box
(provided with the unit) in case the
fan is installed at a later date.
Fan
Green
OFF
Black
Red
Red
Fan Thermodisc
(normally open)
Gas
In
43