5

Install ROPS

Parts needed for this procedure:
1
ROPS frame
4
bolt 1/2 x 3" in.
4
Locknuts 1/2
Procedure
1. Insert each side of ROPS into mounting bracket
on each side of vehicle frame, positioning ROPS as
shown in Figure 8.
Note: The ROPS cover plate mounting bolts may
have to be loosened to insert the ROPS into the
mounting brackets.
2. Secure each side of ROPS to mounting brackets with
(2) 1/2–13 x 3" lg. bolts and locknuts.
1. ROPS
2. Mounting bracket
Figure 8
3. ROPS cover plate
6
Activate and Charge the
Battery
No Parts Required
Procedure
If battery is not filled with electrolyte or activated, it
must be removed from vehicle, filled with electrolyte
and charged. Bulk electrolyte with 1.260 specific gravity
can be purchased from a local battery supply outlet.
CALIFORNIA
Proposition 65 Warning
Battery posts, terminals, and related
accessories contain lead and lead compounds,
chemicals known to the State of California
to cause cancer and reproductive harm.
Wash hands after handling.
Battery electrolyte contains sulfuric acid which
is a deadly poison and causes severe burns.
• Do not drink electrolyte and avoid contact
with skin, eyes or clothing. Wear safety
glasses to shield your eyes and rubber gloves
to protect your hands.
• Fill the battery where clean water is always
available for flushing the skin.
1. Loosen knobs securing battery cover to battery base
and slide cover off.