Xerox WorkCentre 7132 User Manual page 417

Hide thumbs Also See for WorkCentre 7132:
Table of Contents

Advertisement

Xerox WorkCentre 7132 User Guide
Downloaded From ManualsPrinter.com Manuals
Code
018-794
An LDAP server protocol error occurred in the address book operation. The
server returned the RFC2251 specification protocol error 94 (result no longer
available) during the address book query. Check the LDAP server status.
018-795
An LDAP server protocol error occurred in the address book operation. The
server returned the RFC2251 specification protocol error 95 (result still
available) during the address book query. Check the LDAP server status.
018-796
An LDAP server protocol error occurred in the address book operation. The
server returned the RFC2251 specification protocol error 96 (client loop
detected) during the address book query. Check the LDAP server status.
018-797
An LDAP server protocol error occurred in the address book operation. The
server returned the RFC2251 specification protocol error 97 (maximum number
of reference hops exceeded) during the address book query. Check the LDAP
server status.
024-742
The number of print pages, using print options, in a booklet creation job exceeds
the number of maximum pages. Divide the job into manageable jobs or cancel
book creation.
024-746
The selected option (i.e., paper size, document tray, output tray, or double-sided
printing) is incompatible with the specified paper quality. Check the print data.
024-747
An invalid print parameter combination was set. Check the print data. For
example, a custom size was specified, and [Paper Supply] was set to [Auto]. In
this case, select the bypass tray.
024-985
An error occurred in the bypass tray. Check the document size, orientation, and
paper type, then try executing the same operation again.s
026-700
A protocol which is not supported on the machine was received from the LDAP
server during an address book query. Try executing the same operation again.
Contact the Xerox Welcome Center if the problem persists.
026-701
The number of address book requests exceeded the handling capacity of the
machine. Wait a while, and perform the same operation again. If there is only
one address book request, the problem may be in the machine software.
Contact the Xerox Welcome Center.
026-702
The number of transactions from the LDAP server exceeded the handling
capacity of the machine. Wait a while and perform the same operation. Contact
the Xerox Welcome Center if the problem persists.
027-452
The specified IP address already exists. Change the IP address.
027-500
Unable to resolve the name of the SMTP server when reply e-mail was
transmitted. Check from CentreWare Internet Services to see if the SMTP
server is set correctly.
027-501
Unable to resolve the name of the POP3 server when using the POP3 protocol.
Check from CentreWare Internet Services to see if the POP3 server is set
correctly.