3.5.2 Power Cable Connection

Conditions for Power Supplies
• Observe the following conditions:
Alternate Current (AC)
Power Supply Frequency
• Use a voltage regulator when the power supply is not stable.
• The maximum power consumption of this MFP is 980W. Confirm that the power supply has
sufficient extra capacity.
• Never fail to switch off the power supply at the time of connection or removal of the electric
cord and earth cable.
• Always connect the earth cable to the earth terminal equipped only for that purpose. Never
connect the earth cable with water pipe, gas pipe, telephone cable earth terminal, lightening
rod, etc.
• Always grasp the power plug at the time of connection and removal of the electric cord.
• Always make sure that the electric plug is inserted fully into the outlet.
• Do not connect or disconnect the electric plug with the wet hand.
• Do not install the electric cord at the place liable to be stepped on and do not put things on
the electric cord.
• Do not bundle up or tie up the electric cord
• Do not use the damaged electric cord.
• Do not put many loads on one electric outlet.
• Do not connect this MFP to the same outlet with other electric machines. Particularly,
erroneous operation may occur by electric noise when the same outlet is shared by the air
conditioner, duplicator, shredder, etc. at the same time. When the same outlet had to be used,
use a noise filter or noise cut transformer on the market.
• Use the attached electric cord only.
• Do not use an extension cord. Use the cord of over rating 15A if you had to use one.
• When you use the extension cord, the MFP may not operate normally due to the drop of AC
voltage.
• Do not shut down the power supply or remove the power plug while printing.
• Disconnect the power cord when the MFP would not be used for some long while due to
consecutive holidays or journey.
As to the connection of the electric cord and earth cable, explain fully to the customer showing
the User's Manual.
43605601TH Rev. 1
: 110 ~127VAC(Range 99~140VAC)/220 ~240VAC(Range
198~264VAC)
: 50Hz or 60Hz±2%
It may expose you to electric shocks or cause a fire.