7.5.2.(8) ID Unit Up-Down Error (Service Call 140-143)

(8-1)

Error occurred during ID unit up operation

Confirmation Items
(8-1-1) Check the load during up operation
Load when ID unit is
attached or removed
Up-and-down link lever
grease of right-and-left
side
Assembly of up-and-down
link lever of right-and-left
side
(8-1-2) Up-and-down mechanism
Assembly condition
around link lever
Left-and-right link lever
(8-1-3) Check the sensor
Up-and-down sensor lever
(which is integrated with
left link lever)
Up-and-down sensor

(8-2) Error occurred during ID unit down operation

Confirmation Items
(8-2-1) Check the load during down operation
Load when ID unit is
attached or removed
Up-and-down link lever
grease of right-and-left
side
Assembly of up-and-down
link lever of right-and-left
side
43605601TH Rev. 1
Confirmation Tasks
Check whether abnormal load exists when ID unit is
attached or removed.
Check whether the slant of link lever is greased up.
Check whether the parts around the link lever that may
disturb the movement of link lever exist. (Cable etc.)
Check whether the link lever is connected with planet
gear.
Is the link lever set correctly in position of
engagement?(Check whether the set position of link
lever is out of gear tooth.)
Check whether there is something abnormal about the
form of sensor lever and its movement.
Switch scanning test function of the maintenance
utility.
Confirmation Tasks
Check whether abnormal load exists when ID unit is
attached or removed.
Check whether the slant of link lever is greased up.
Check whether the parts around the link lever that
may disturb the movement of link lever exist. (Cable
etc.)
Oki Data CONFIDENTIAL
Action at NG
Replace the ID unit
or right-and-left side
plate with new one.
When trying to
use a new ID unit,
please be careful
not to break the
fuse with jig inside
the ID unit. (Please
refer to page 132)
Spread the grease
evenly.
Assemble correctly.
Assemble correctly.
Assembly correctly.
Replace the left link
lever with a new
one.
Replace the high-
voltage board with
a new one.
Action at NG
Replace the ID unit
or right-and-left
side plate with new
one.
Spread the grease
evenly.
Assemble correctly.