Alternator Exciter Coil Peak Voltage - Honda 2000 XR50R Service Manual

Table of Contents

Advertisement

If
the
peak
voltage measured at
reM
connector is
abnormal, measure the
peak voltage
at
the
pulse
generator
connector.
Disconnect the ignition pulse generator connector
(bluelyellow) and connect the peak voltage adaptor
or tester
probes
to
the
connector terminal of the
ignition pulse generator
side and
ground.
In the
same
manner
as
at the
leM
connector,
meas-
ure
the
peak
voltage
and
compare
it
to
the voltage
measured at the leM
connector.
• If
the peak voltage
measured
at
the leM is
abnor-
mal
and the one measured at
the
ignition
pulse
generator
is
normal,
the wire harness
has
an
open circuit or
loose connection
.
• If both peak
voltages
are
abnormal,
follow the
checks
described
in
the troubleshooting
chart
(page
14-2).
ALTERNATOR EXCITER COIL PEAK
VOLTAGE
Avoid touching the
sp.rk
plug .nd
tester probes to
prevent
electric shock.
NOTE
:
Check.
cylinder
compression and
check.
that the
spark.
plug
is
installed correctly.
Remove the
seat assembly
(page
2-2).
Disconnect the
3P and
2P
connectors from the
ICM.
Connect the peak
voltage
adaptor
or
peak
voltage
tester probes to the
connector
terminals of the
wire
harness side.
TOOLS:
Peak vottage
tester (U.S.A. only) or
Peak vottage
adaptor
07HGJ
-
0020100
(not
availabte In
U.S.A.!
with
commercially availa-
ble digital muttimeter
(impedance
10M
Q
loeV
minimum)
CONNECTION:
Black/Red terminal {+)
-
Green {
-
I
Shift the transmission
into
neutral.
Crank the engine with kickstarter and read the peak
voltage.
PEAK VOLTAGE:
l00V minimum
IGNITION SYSTEM
IGNJTION PULSE GENERATOR CONNECTOR
ICM CONNECTORS
14-5