How User Charts Are Synced - Furuno FMD-3200 Operator's Manual

Electronic chart display and information system
Hide thumbs Also See for FMD-3200:
Table of Contents

Advertisement

10. USER CHARTS
• Circle: The operator can define an area with a circle, which can define a location to
avoid. If route or estimated ship position is going to cross the area, the system gen-
erates a warning to the user. These areas can be used to specify safe areas as de-
fined by the master or by the policy of the ship's owner. They are always available
regardless of the type of chart material used.
• Labels: There are two types of labels: point and label. A "point" (i) is mainly used to
denote position of objects, such as buoys, light houses, fixed targets, wrecks, etc.
Points can be used in chart alert calculation. A "label" provides user-entered text to
show on the display.
10.2

How User Charts are Synced

User chart data can be shared between this ECDIS and other like units (FMD-3x00,
FCR-2xx9, FAR-3xx), through the LAN. Turn on all units beforehand to enable sync-
ing. The unit first powered becomes the master unit (sync source), and the user chart
data are automatically synced by the sync source. The unit selected as the sync
source depends on the number of units connected, as shown in the table below. If the
power of the initial sync source is turned off, the 2nd unit turned on becomes the sync
source.
Number of units
ECDIS
(FMD-3xx0)
One unit
Two or more units
Be aware that if a unit is turned off, some user chart data may be deleted. The steps
below illustrate this using ECD001 and ECD002.
1. ECD002 is off; ECD001 is powered and a user chart is created at ECD001.
(Sync source: ECD001)
2. The power to ECD001 is turned off. ECD002 was turned off at step 1, therefore
the user chart is not delivered to ECD002.
3. ECD002 and ECD001 are powered in that order. (Sync source: ECD002)
Because the sync source became ECD002, the user chart created at step 1 is de-
leted.
10-2
Chart Radar
(FCR-2xx9, FAR-3xx)
One unit
More than one unit
Sync source
The unit (ECDIS or chart radar) first powered be-
comes the sync source and syncs user chart data.
The ECDIS unit (No. 1 ECDIS or No. 2 ECDIS) first
powered syncs user chart data (a chart radar can-
not be the sync source). However, if a "Planning
ECDIS" is used, the Planning ECDIS syncs the
route data. (Planning ECDIS usage/no usage is
set at installation.)