24. MAINTENANCE AND TROUBLESHOOTING
24.2

How to Replace the Fuse

The fuse in the Processor Unit, Monitor Unit and Sensor Adapter protects those units
from overvoltage (overcurrent) and internal fault. If a unit cannot be turned on, check
if its fuse has blown. If a fuse has blown, find out the cause before replacing the fuse.
If the fuse blows again after replacement, contact your dealer for advice.
Unit
Processor Unit
EC-3000
Monitor Unit
MU-190
Monitor Unit
MU-231
Sensor Adapter
MC-3000S
24-2
WARNING
Use the proper fuse.
Use of a wrong fuse can damage the
equipment or cause fire.
Power supply
100-115 VAC
220-230 VAC
100-230 VAC
100-230 VAC
24 VDC
Type
FGMB 125V 10A PBF
FGMB 250V 5A PBF
FGBO 250V 1A PBF
FGBO 250V 1.5A PBF 000-155-833-10
FGMB 125V 3A PBF
Code no.
000-157-470-10
000-157-570-10
000-155-828-10
000-157-481-10