APPENDIX 5 ALERT LIST

No.
Text
001
Fan1 Rotation
Speed Lowering
002
Fan2 Rotation
Speed Lowering
003
Fan3 Rotation
Speed Lowering
004
Fan4 Rotation
Speed Lowering
005
LCD Unit
Lifetime Over
006
High Temperature
Inside Monitor
007
Fan1 No
Rotation
008
Fan2 No
Rotation
009
Fan3 No
Rotation
010
Fan4 No
Rotation
011
RS485 Communi-
cation Timeout
Default
Meaning
Caution
For MU-190/231: Connect-
ed to COM1(Main Monitor).
Fan1 rotation speed is be-
low threshold.
Caution
For MU-231: Connected to
COM1(Main Monitor).
Fan2 rotation speed is be-
low threshold.
Caution
For MU-231: Connected to
COM1(Main Monitor).
Fan3 rotation speed is be-
low threshold.
Caution
For MU-190: Connected to
COM1(Main Monitor).
Fan4 rotation speed is be-
low threshold.
Warning
For MU-190: Connected to
COM1. LCD unit operating
time exceeds 50000 hours.
For MU-231: Connected to
COM1. LCD unit operating
time exceeds 50000 hours.
Warning
Internal temperature ex-
ceeds threshold.
Monitor: Connected to
COM1 (Main Monitor).
Warning
For MU-190/231: Connect-
ed to COM1 (Main Monitor).
Fan1 rotation speed is be-
low threshold.
Warning
For MU-190/231: Connect-
ed to COM1 (Main Monitor).
Fan2 rotation speed is be-
low threshold.
Warning
For MU-231: Connected to
COM1 (Main Monitor).
Fan3 rotation speed is be-
low threshold.
Warning
For MU-190: Connected to
COM1 (Main Monitor).
Fan4 rotation speed is be-
low threshold.
Caution
For MU-190/231: Connect-
ed to COM1. There has
been no communication
from processor unit through
RS485 for 180 seconds.
(No communication implies
in completed sentence or
checksum error.)
Remedy
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
LCD unit replacement is re-
quired. Contact FURUNO.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
Check the connection of
brightness control cable.
AP-35