APPENDIX 5 ALERT LIST
No.
Text
035
Sensor Adapter 6
COM Timeout
036
Sensor Adapter 7
COM Timeout
037
Sensor Adapter 8
COM Timeout
038
Sensor Adapter 9
COM Timeout
039
Sensor Adapter 10
COM Timeout
070
RCU 1 COM
Timeout
071
RCU 2 COM
Timeout
072
RCU 3 COM
Timeout
073
EC-3000 CPU
Temp High
074
EC-3000 GPU
Temp High
075
EC-3000 CPU
Board Temp High
AP-38
Default
Meaning
Caution
Communication error with
No.6 sensor adapter is de-
tected. 30 seconds timeout.
No.6 sensor adapter is
turned off, or there is a prob-
lem with network.
Caution
Communication error with
No.7 sensor adapter is de-
tected. 30 seconds timeout.
No.7 sensor adapter is
turned off, or there is a prob-
lem with network.
Caution
Communication error with
No.8 sensor adapter is de-
tected. 30 seconds timeout.
No.8 sensor adapter is
turned off, or there is a prob-
lem with network.
Caution
Communication error with
No.9 sensor adapter is de-
tected. 30 seconds timeout.
No.9 sensor adapter is
turned off, or there is a prob-
lem with network.
Caution
Communication error with
No.10 sensor adapter is de-
tected. 30 seconds timeout.
No.10 sensor adapter is
turned off, or there is a prob-
lem with network.
Caution
Communication error with
No.1 remote control unit is
detected. 40 seconds time-
out.
Caution
Communication error with
No.2 remote control unit is
detected. 40 seconds time-
out.
Caution
Communication error with
No.3 remote control unit is
detected. 40 seconds time-
out.
Caution
CPU temperature in proces-
sor unit exceeds threshold.
Caution
CPU temperature in proces-
sor unit exceeds threshold.
Caution
CPU temperature in proces-
sor unit exceeds threshold.
Remedy
Check the connection with
No.6 sensor adapter and
network.
Check the connection with
No.7 sensor adapter and
network.
Check the connection with
No.8 sensor adapter and
network.
Check the connection with
No.9 sensor adapter and
network.
Check the connection with
No.10 sensor adapter and
network.
Check the connection with
No.1 remote control unit.
Check the connection with
No.2 remote control unit.
Check the connection with
No.3 remote control unit.
Turn off Processor Unit. If
same error occurs after a
few minutes, contact FU-
RUNO.
Turn off Processor Unit. If
same error occurs after a
few minutes, contact FU-
RUNO.
Turn off Processor Unit. If
same error occurs after a
few minutes, contact FU-
RUNO.