ESIE05-03
5.9.5
Outdoor unit: Check Low Pressure Sensor
Measure the voltage (DC) between pins 2 and 3 of the connector.
n
Microcomputer
A/D input
Detected Pressure
(Kg/cm²)
P
P
V: Voltage (V)
Part 3 – Troubleshooting
For RZQ71 models
Outdoor unit PC board
+5V
Measure voltage (DC) here.
P
, P
H
L
MPa
51.0
5.0
45.9
4.5
40.8
4.0
35.7
3.5
30.6
3.0
25.5
2.5
20.4
2.0
15.3
1.5
10.2
1.0
5.1
0.5
0
0
-5.1
-0.5
-0.5
0
0.5
1
1.5
Output voltage (V
= 0.57V-0.28
P
L
L
: Low pressure (MPa)
V
: Output voltage (Low side) Vdc
L
L
Additional Checks for Troubleshooting
(Blue)
Red
ƒ
Black
Low pressure sensor
White

Low Pressure (P
)
L
2
2.5
3
3.5
4
Vdc
)
L
= Detected Presuure (Low side) MPa
(V3053)
1
3 3
(S2680)
4
5
3–115