Daikin RZQ100B8V3B Service Manual page 260

Hide thumbs Also See for RZQ100B8V3B:
Table of Contents

Advertisement

Additional Checks for Troubleshooting
5.9.2
Outdoor Unit: Fan Motor Signal Line
1
3
3
4
5
3–112
For RZQ71~140 models
(1) Turn the power supply off.
(2) With the fan motor connector disconnected, measure the resistance between each pin, then make
sure that the resistance is more than the value mentioned in the following table.
1 White
2 Orange
3 Brown
GND
4 Blue
5
6
7 Red
Measurement point
1 - 4
2 - 4
3 - 4
4 - 7
(S2675)
ESIE05-03
Judgment
1MΩ or more
100kΩ or more
100Ω or more
100kΩ or more
Part 3 – Troubleshooting

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rzq71b8v3bRzq125b7w1bRzq125b8v3bRzq140b7w1bRzq100b7w1b

Table of Contents