• TemperatureTooHigh (Warning) - this fault is raised when the internal temperature of the
enclosure is equal to or exceeds the value MAX_TEMPERATURE held in ENVM.conf. Once an
alarm is generated and the temperature drops to a level 1 degree below the
MAX_TEMPERATURE value the fault is then automatically cleared. This is to avoid transient
changes in temperature around the threshold.
• TemperatureTooLow (Warning) - a fault is raised when the internal temperature of the
enclosure is equal to or is below the value MIN_TEMPERATURE held in ENVM.conf. Once an
alarm is generated and the temperature drops to a level 1 degree above the
MIN_TEMPERATURE value the fault is then automatically cleared. This is to avoid transient
changes in temperature around the threshold.
• TemperatureOrHumiditySafeMode (Error) - the "Safe ON" and "Safe OFF" operational modes
indicate that the environmental card software detected a failure in the temperature or humidity
sensor and turned the blowers and heaters to the safe default state. The blower safe default
state is "Safe ON". The heater safe default state is "Safe OFF".
Procedure 8-9 Display Current Faults
Step
Action
Select Current Faults from the Information menu.
1
The current faults tab displays.
Procedure 8-10 Delete Current Faults
Step
Action
Select Current Faults from the Information menu.
1
The current faults tab displays.
Select the corresponding Delete check box to mark the fault for deletion.
2
Or
Deselect the corresponding Delete check box to keep the fault.
Note
Select the Select All check box to mark all faults displayed in the list for deletion.
Select Delete to delete the selected faults.
3
You will be prompted to confirm the deletion.
Select OK to confirm the deletion.
4
Or
Select Cancel.
8-106
- End -