Current Faults

Current Faults
When Current Faults is selected information will be displayed on the following:
• # - details the fault index.
• Fault - a description of the fault.
• Date created - the time and date when the fault occurred.
• Component - internal software component that raised the fault either DIOM (Digital Input Output
Monitor) or ENVM (Environmental Monitor).
• Severity - indicates how serious the fault is. The following are supported, in increasing order of
severity, Clear, Warning, Critical and Error.
• Detail - extra information that supplements the fault description.
• Delete -remove the fault from the fault table.

Fault Details

DIOM (Digital Input Output Monitor) Component

The following faults can be raised by the DIOM (Digital Input Output Monitor) component when
using the Illustra 625 PTZ Camera Feature Plus:
• DigitalAlarmInForce
• DigitalRaiseInputAlarm1
• DigitalRaiseInputAlarm2
• DigitalRaiseInputAlarm3
• DigitalRaiseInputAlarm4

System Faults

The following system faults may be raised:
• DiskUsage(Warning) - this warning is raised when the disk utilisation rises above the threshold
value "threshold2" held in SYSM.conf. Once an alarm is generated and the disk utilization
decreases 1% below the threshold value, the fault is then automatically cleared. The default
threshold value is 80%.
• PowerSupplyAlarm(Error) - this fault is raised when one or more of the internal DC power
supplies voltage level is either too high or too low. Once an alarm is generated and the DC
power voltage goes back into the proper range, the fault is then automatically cleared.

ENVM (Environmental Monitor) Component

If an environmental card is used the following faults can be raised by the ENVM (Environmental
Monitor) component:
• BlowerConditionFaulty (Error) - the blower condition may be GOOD or FAIL. Since the
environmental card hardware contains two blowers, the reported condition is the worst for both
blowers. Therefore, if one blower fails, but the other works correctly, the condition will be
reported as "Fail".