Nanoe-G Operation - Panasonic CS-VE9NKE Service Manual

Hide thumbs Also See for CS-VE9NKE:
Table of Contents

Advertisement

12.10

nanoe-G Operation

This operation provides clean air by producing great amount of negative ions and distribute through the
discharge airflow to capture or deactivate molds, bacteria or viruses.
nanoe-G ON/OFF condition
Priority
"No NANOE-G" is selected during model selection.
During Demo mode
1
Two-way communications on remote control
NANOE-G connector open
NANOE-G error (circuit error & abnormal discharge detection)
Inspection mode NANOE-G ON command
2
Inspection mode NANOE-G OFF command
No "NANOE-G" setting on the remote control
Operation status: OFF
During NANOE-G restart prohibiting time
3
(Prohibiting time is set in the case of abnormal discharge and room temperature of 40°C
and above. Details will be provided later.)
During FM OFF; or FM rotation speed is less than 490 rpm
Ordinary vertical louver selected; or Airflow
direction is not set to ceiling airflow or DOWN
4
Twin louver is selected; or airflow direction is ceiling airflow or DOWN
 ON/OFF intermittent output
nanoe-G operation pause condition
When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe-G operation resume after
o
indoor fan restarts.
When indoor intake temperature ≥ 40°C. nanoe-G operation resume after indoor intake temperature ≤ 40°C
o
continuously for 30 minutes.
Indoor fan control
During any operation mode combines with nanoe-G operation, fan speed follows respective operation mode.
o
However, nanoe-G system enabled when fan speed ≥ 490 rpm to ensure proper negative ion distribution,
nanoe-G system disabled when fan speed < 490 rpm.
Airflow direction control
During any operation mode combines with nanoe-G operation, airflow direction follows respective operation
o
mode.
During nanoe-G individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no
o
signal is sent to the unit and no change on remote control display.
Timer control
When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe-G
o
operation status.
When ON Timer activates during any operation, no change on current operation.
o
When OFF Timer activates during any operation, all operation stops and the latest nanoe-G operation status
o
is saved.
Indicator
When nanoe-G starts, nanoe-G indicator ON.
o
Item
Less than 60 minutes have elapsed
since the start of Powerful
individual fan operation.
Other than above
43
Output
OFF
OFF
OFF
ON/OFF
intermittent output
as mentioned
below
ON
ON

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-ve12nkeCu-ve9nkeCu-ve12nke

Table of Contents