12.12.1.6
Area of Living Classification Judgment
The system is able to judge area of living according to human activity database, classified as following:
(Zone I ) Living Area - In front of television, dining table, etc.
o
(Zone II) Walkway - Human detection is relatively less.
o
(Zone III) Non-Living Area - Near windows, wall, etc.
o
12.12.1.7
Target Area and Position Judgment
By default, the system will judge the indoor unit installation position according to human activities and will reset
the louver center position:
Non-Living Area at Position A - Indoor unit is installed at left side of the room, louver center position set to
o
right side.
Non-Living Area at Position C - Indoor unit is installed at right side of the room, louver center position set to
o
left side.
Other than above - Indoor unit is installed at center of the room, louver position set to center.
o
Every 4 hours, the Target Area and Position Judgment will restart.
If the indoor unit installation position is set by remote control, the above judgement will be ignored.
12.12.2 Setting Temperature and Fan Speed Shift
Cooling Dual Sensor