Panasonic CS-VE9NKE Service Manual page 37

Hide thumbs Also See for CS-VE9NKE:
Table of Contents

Advertisement

12.2.2
CS-VE12NKE
Fan speed: Manual
Normal (with programmed air)
Powerful
Long Right/Left
Initial
Long Other than
airflow
Right/Left
When the area control
is in operation
Powerful
Fan
Long Right/Left
speed:
Airflow
Long Other than
Auto
stable /
Right/Left
unstable
When the area control
is in operation
Normal
Cool dry
Powerful/Long
Initial
When the area control
airflow
is in operation
Powerful/Long
Airflow
stable /
When the area control
unstable
is in operation
Fan speed: Manual
Normal
At the start of
Powerful /
operation
Fan
Long
Not at the start of
speed:
operation
Auto
When the area control is in
operation
Clothes drying
Fan speed: Manual
Unstable
Normal
Stable
Powerful
Long Right/Left
Initial
Long Other than
airflow
Fan
Right/Left
speed:
When the area control
Auto
is in operation
Powerful
Long Right/Left
Airflow
Long Other than
stable /
Right/Left
unstable
When the area control
is in operation
Hot Dry
Fan speed: Manual
Individual ventilation /
NANOE
Odor Cut Shift
Only for the COOL and COOL range
* Lock detection: When the rotation speed of 2550rpm and above or below 50rpm is detected for 10 consecutive seconds during the feedback
control, H19 is indicated (the TIMER indicator flashes) if normal rotation speed is not detected even after the retry is performed 7 times.
* Refer to the attached list of "Indoor Unit Fan Operation Status" for the operations of the indoor unit fan while the thermostat is OFF.
Stop
SSLo
O
Outside temperature is below 35°C or Neuro is
O
stable.
1240 (SHi) (1190 when the setting is changed from Hi to Powerful on the remote control.)
1300 (SHi) (1190 when the setting is changed from Hi to Long on the remote control.)
1260 (SHi) (1190 when the setting is changed from Hi to Long on the remote control.)
O
O
O
920  1260 (1340 when the setting is changed from Hi to Powerful on the remote
920  1440 (1340 when the setting is changed from Hi to Long on the remote control.)
920  1280 (1340 when the setting is changed from Hi to Long on the remote control.)
O
Fan speed: Auto
Indicates the changeable range using the remote control
SLo
Quiet Lo
480
640
650
MIN 640 ± 50 ~ 910 ± 50rpm
710  1040
730  1080
730  1060
(1) 710  1040
Range 2 640
Range 1 730
640  830
(1) 640  830
---
---
550
Min. rotation speed for each of the following fields
380
540
720
control.)
1000  1140
1000  1120
650
500
Below Lo: No shifting
Below Me and fan speed auto: 20
37
Lo-
Lo
Me-
650
730
870
1010
Outside temperature is 35°C or higher
and Neuro is unstable.
1010
730
1010
---
690
790
750
720
820
960
1100
920  1140
940  1140
920  1260
980  1100
(1) 980  1100
max 820
730
870
1010
Me
Hi
SHi
1100 ~
---
1190
970 ± 50rpm
890
990
---
1230
1090
1230
1240 ~
---
1340
1160
---
Me and above: 90