Vertical Airflow - Panasonic CS-VE9NKE Service Manual

Hide thumbs Also See for CS-VE9NKE:
Table of Contents

Advertisement

12.4.1

Vertical Airflow

Airflow
direction:
Manual
AUTO
Discharge
temperature
is high.
1-4: Preset
angle (10-50°)
5: Preset
Discharge
angle 60°
HEAT
temperature
(57° when
is medium.
there is no
airflow
towards feet.)
Discharge
temperature
is low.
1: Ceiling
airflow
COOL
2-5: Preset
angle (10-50°)
COOL DRY
1: Ceiling
Mild Dry Cooling
airflow
(For the models of
2-5: Preset
6.3kW and above
angle (10-40°)
only)
Same as the
manual
DRY
setting in
COOL mode.
Vertical Airflow Direction Louver
Normal
Powerful
2.2 ~ 3.6kW : 57°
4.0 ~ 5.6kW : 51°
6.3 ~ 7.1kW : 48°
Unstable:
Initial airflow:
10-40°
30°
(Swing)
Other than
Stable: 10-35°
initial airflow:
(Swing)
10°
Ceiling airflow
(No powerful setting for Mild
Dry Cooling)
Initial
airflow: 30°
Other than
Ceiling airflow
initial airflow:
Ceiling
airflow
Airflow direction: Auto
Long
According to each mode
35°
Horizontal airflow
direction
When "Front, Spot or
Wide" is set:
When the furniture position has been set on the
40°
remote control, the airflow direction is set
When "Slightly Right or
Slightly Left" is set:
4.0kW and above: Human detecting direction
40°
When the furniture position has been set on the
remote control, the airflow direction is set
When "Right or Left" is
set:
When the human detection sensor detects an
68° (upper louver)
obstacle automatically, the airflow direction is
60° (lower louver)
10°
Airflow unstable: Human detecting direction
Horizontal airflow
3.6kW or below:
direction
When the furniture position has been set on the
When "Front, Spot or
remote control, the airflow direction is set
Wide" is set:
upward according to the setting.
20°
4.0kW and above:
When the furniture position has been set on the
When "Slightly Right or
remote control, the airflow direction is set
Slightly Left" is set:
upward according to the setting.
30°
When the human detection sensor detects an
obstacle automatically, the airflow direction is
When "Right or Left" is
set upward according to the detection.
set:
66° (upper louver)
60° (lower louver)
Drying unstable: Human detecting direction
3.6kW or below:
When the furniture position has been set on the
remote control, the airflow direction is set
upward according to the setting.
No setting is available.
4.0kW and above:
When the furniture position has been set on the
Louver direction can be
remote control, the airflow direction is set
set when the "Auto
upward according to the setting.
Comfort" is set.
When the human detection sensor detects an
At this time, the angle is
obstacle automatically, the airflow direction is
the same as the Cool
set upward according to the detection.
Long mode if the mode
set is other than the
HEAT mode.
39
Sensor
Normal
3.6kW or below: 60°
(Slightly upward when there is no airflow
towards feet.)
upward according to the setting.
upward according to the setting.
set upward according to the detection.
Airflow stable: Ceiling airflow
Drying stable: Ceiling airflow
Ceiling airflow