14.11 Indication Panel

LED
Color
Light ON
Operation ON
Light OFF
Operation OFF Timer Setting OFF nanoe OFF ECONAVI OFF
Note:
If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operation
mode judgment, or ON timer sampling.
If Timer LED is blinking, there is an abnormality operation occurs.

14.12 nanoe Operation

This operation provides clean air by producing great amount of negative ions and distribute through the
discharge airflow to capture or deactivate molds, bacteria or viruses.
Generate nanoe (water wrapped ion particle) to moisturize skin.
nanoe operation start condition
During unit running at any operation mode, if nanoe operation is activated, combination operation (operation
o
mode + nanoe operation) starts.
During unit is OFF, if nanoe operation is activated, nanoe individual operation starts.
o
nanoe operation stop condition
When OFF/ON button is pressed to stop the operation.
o
When nanoe button is pressed.
o
When OFF Timer activates.
o
nanoe operation pause condition
When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe operation resume after
o
indoor fan restarts.
When indoor intake temperature ≥ 35°C and < 5°C. nanoe operation resume after indoor intake temperature
o
< 35°C or ≥ 5°C continuously for 6 minutes.
Indoor fan control
During any operation mode combines with nanoe operation, fan speed follows respective operation mode.
o
However, nanoe system enabled when fan speed ≥ 470 rpm to ensure proper negative ion distribution,
nanoe system disabled when fan speed < 470 rpm.
During nanoe individual operation, only Auto Fan Speed and no Powerful operation is allowed. Even if Fan
o
Speed button is pressed, no signal is sent to the unit and no change on remote control display. Auto Fan
Speed for nanoe individual operation is cooling medium fan.
Airflow direction control
During any operation mode combines with nanoe operation, airflow direction follows respective operation
o
mode.
During nanoe individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no
o
signal is sent to the unit and no change on remote control display.
Timer control
When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe
o
operation status.
When ON Timer activates during any operation, no change on current operation.
o
When OFF Timer activates during any operation, all operation stops and the latest nanoe operation status is
o
saved.
Indicator
When nanoe starts, nanoe indicator ON.
o
POWER
TIMER
White
White
Timer Setting ON nanoe ON
nanoe
ECONAVI
White
White
ECONAVI ON