General; Schematic; Specifications (Standard) - Mitsubishi S3L Service Manual

Sl series
Hide thumbs Also See for S3L:
Table of Contents

Advertisement

GENERAL

Figure 204 Schematic
Engine model
Fan belt (for farm or industrial engine)
Cooling fan
Suction type
Water pump
Temperature at which valve
starts opening
Thermostat
Temperature at which valve lift
is 8 mm (0.3 in.)
Type
Temperature at which switch
Thermo
is turned ON
switch
Temperature difference for
ON-OFF control
Resistance in thermounit
136 / 195
136 / 195
Radiator
Cooling fan
No. of blades = 5,
diameter = 320 mm (12.6 in.)
COOLING SYSTEM
34 GENERAL

34.1 Schematic

Water bypass hose
Thermostat
Water pump

34.2 Specifications (standard)

S3L/S3L2
LL or HM type (width = 10.7 mm (0.42 in.), V angle = 38°, outer
circumference = 980 mm (38.6 in.)
Centrifugal type
82 ± 1.5°C (180 ± 2.7°F)
111 ± 3.5°C (232 ± 6.3°F)
8 ± 3.5°C (46.4 ± 6.3°F)
50°C (122°F): 80 ± 10 Ω
80°C (176°F): 29.5 ± 2.5 Ω
120°C (248°F): 10 ± 0.3 Ω
1. All specifications are subject to change without any prior
notice.
ENGLISH
Service Manual Mitsubishi SL-Series diesel engines
COOLING SYSTEM
S4L/S4L2
No. of blades = 5,
diameter = 360 mm (14.2 in.)
95°C (203°F)
Bimetal
1
Version 08/2004