Shutoff Solenoid Installation - Mitsubishi S3L Service Manual

Sl series
Hide thumbs Also See for S3L:
Table of Contents

Advertisement

ELECTRICAL SYSTEM
Tie rod
Rack at no-injection
end position
Push rod in free-to-
move state
Apply sealant
Tightening torque:
49 N·m {5 kgf·m}
(36 lbf·ft)
NOTE:
Areas A must be free of sealant.
Service Manual Mitsubishi SL-Series diesel engines
Version 08/2004
KEY SHUTOFF SYSTEM (ETR solenoid

32.3 Shutoff solenoid installation

1.
Remove the tie rod cover on the injection pump to
enable movement of the rack to be observed.
2.
Put the nut 2 on the solenoid 1 and turn the nut
down to the inner end of the threads on the
solenoid.
Apply sealant to the threads on the solenoid.
NOTE
Sealant should be applied over those threads which
are concealed when the solenoid is installed on the
cylinder block.
Sealant
3.
Screw the solenoid 1 into the cylinder block.
4.
While moving the rack in both directions, screw in
the solenoid 1 until the rack is against the
solenoid's push rod and cannot move any more.
5.
Unscrew the solenoid 1 approximately 90 – 180°
from the position achieved in (d), and temporarily
lock the solenoid with the nut 2.
6.
Move the rack in both directions. There should be
a play of approximately 0.3 – 0.7 mm (0.01 – 0.03
in.).
7.
Tighten the nut 2 to the specified torque.
Nut tightening torque
8.
Reinstall the tie rod cover on the injection pump.
9.
Start the engine. Turn the starter switch to the OFF
position. The push rod then should extend,
pushing back the rack and stopping the engine.
NOTE
It will take about 10 seconds to restart an engine
which was shut down by the key shutoff device.
ENGLISH
type)
Threebond 1212 or 1211
Threebond 1212 or 1211
131 / 195

Advertisement

Table of Contents
loading

This manual is also suitable for:

S3l2S4lS4l2

Table of Contents