Important Note - NAPCO Gemini GEM-P816 Programming Instructions Manual

Table of Contents

Advertisement

THIS MANUAL INCLUDES FEATURES WHICH ARE ONLY AVAILABLE IN CONTROL PANEL FIRMWARE
VERSION 10 OR LATER.
This manual supports the keypad programming of the GEM-P816 control panel with the NAPCO "classic" GEM-
RP1CAe2 keypad as well as the GEM-K1CA "K Series" keypad. The new "K Series" GEM-K1CA model offers the new
STAY and AWAY buttons with simplified functionality, along with the new MENU and ENTER buttons.
While the instructions in this manual are depicted using the GEM-K1CA keypad, the manual applies to both the "classic"
and the "K Series" keypads.
Program Mode is the same for both keypads--only the button names have changed, as follows:
A
• The
button and the
D
• The
button and the
• The
button and the
"NEXT/YES button" are used in this manual.
• The
button and the
"PRIOR/NO button" are used in this manual.
The following changes have been made to this manual (WI995C) since the previous edition (WI995B):
Removed the following entries from the index: Change Pulse Output to Cadence, Enable Chirp on RF Arming, Enable Transmitter Telco 1,
Enable Transmitter Telco 3, Select Bell Output on RF Arming.
Page 4, top, "Downloading From a Computer", the following sentence was added: "Unattended downloading from a computer is not allowed
for Fire Alarm or UL installations."
Pages 4, 5, and 7, the "50mS Loop Response Zones" entries now contain the following notation: "Note: 750mS is required for Loop Response
time in UL installations."
Page 7, the "Auto Bypass Re-entry Zones" entry was modified: "Not Evaluated by UL" notation was added.
Page 8, the "Enter User Codes" entry was modified, and now states to "enter a code from 3 to 6 digits."
In the Area Options/Explanation chart at the top of page 9, the following information was added: "Ambush: Allows user code to send Ambush
signal to Central Station".
Top of page 16, under the heading, "Output Timeouts", the following reference was added: "Not UL listed for Commercial Installations".
Page 18, Address 0720, bit 7 (Change Pulse Output to Temporal Output) was modified with the following notation: "This feature must be pro-
grammed in Fire Alarm applications."
Page 18--All references to 0720-Bit 6--"Enable PGM2 Chirp on Keyfob Arming" name changed to "Chirp Output on Keyfob Arm/Disarm".
Page 18--All references to 0722-Bit 0--"Automatic Interior Bypass" name changed to "Automatic Interior Bypass/Easy Exit".
Page 18--All references to 0721-Bit 7--"Enable Bell Output on Keyfob Arming" name changed to "Select Alarm Output for Keyfob Chirp".

IMPORTANT NOTE

R
button operate identically (in Program Mode) for both keypads.
U
button operate identically (in Program Mode) for both keypads.
button operate identically (in Program Mode) for both keypads. The words
button operate identically (in Program Mode) for both keypads. The words
CHANGES FROM PREVIOUS EDITION
333 Bayview Avenue, Amityville, New York 11701
For Sales and Repairs, call toll free: (800) 645-9445
For direct line to Technical Service, call toll free: (800) 645-9440
Internet: http://www.napcosecurity.com
NAPCO Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents