ADDRESS NUMBER INDEX (CONT'D)
ADDRESS
0565
Abort Delay (Enable Zone)
0566
Power-up Delay (Enable Zone)
0567
Day Zone Open (Enable Zone)
0568
Day Zone Short (Enable Zone)
0569
Alarm on Day Zone (Enable Zone)
0570
Alarm Telco 1 (Enable Zone)
0571
Alarm Restore 1 (Enable Zone)
0572
Trouble Telco 1 (Enable Zone)
0573
Trouble Restore 1 (Enable Zone)
0574
Alarm Telco 3 (Enable Zone)
0575
Alarm Restore 3 (Enable Zone)
0576
Trouble Telco 3 (Enable Zone)
0577
Trouble Restore 3 (Enable Zone)
0578
No EOL Resistor (Enable Zone)
0579
Trouble on Open (Enable Zone)
0580
Trouble on Short (Enable Zone)
0581
Zone Area 1 (Enable Zone)
0583
Interior (Stay) Bypass (Enable Zone)
0584
Keypad Sounder on Alarm (Enable Zone)
0586
Fire (C) (Enable Zone)
0587
Fire Alarm Verification (C) (Enable Zone)
0589
Zone ANDing Group 1 (Enable Zone)
0590
Zone ANDing Group 2 (Enable Zone)
0591
Zone ANDing Group 3 (Enable Zone)
0592
Zone ANDing Group 4 (Enable Zone)
0593
Sensor Watch (Enable Zone)
0595
Chime 2 (Enable Zone)
0710
PGM2 Output Timeout
0710
SYSTEM OUTPUT TIMEOUTS
0711
PGM2 Output Access Control Timeout
0711
SYSTEM DELAYS & TIMEOUTS
0712
Alarm Output Timeout
0712
SYSTEM OUTPUT TIMEOUTS
0713
Pulsed Alarm Output Timeout
0713
SYSTEM OUTPUT TIMEOUTS
0714
PGM1 Output Timeout
0714
SYSTEM OUTPUT TIMEOUTS
0715
Abort Delay (Time)
0715
SYSTEM DELAYS & TIMEOUTS
0716
Chime Timeout
0716
SYSTEM DELAYS & TIMEOUTS
0717
AC Fail Report Delay (Time)
0717
SYSTEM DELAYS & TIMEOUTS
0718
Closing Report Only on Conditional Close
0718
Disable Zone Fault Scrolling
0718
Enable AutoArm if not closed at end of Window
0718
Enable Time/Date KP Display
0718
Incl. Sel./Grp. Bypass in Cond. Close /Status
0718
Include Select/Group Bypass in Conditional Close/Status
0718
Opening Report Only after Alarm Report
0718
Status Report
0718-0722
SYSTEM OPTIONS
0719
Access Control on PGM2 Output
0719
Auto Bell Test on Arming
0719
Auto Reset after Burglary Output Timeout
0719
Disable Keypad Instant Mode
0719
Enable Manager's Mode
0719
Enable Local Alarm on First Zone AND Trip
0719
Maintained Keyswitch Arming
0719
Suppress Bypass Reminder when Armed
0720
Change Pulse Output to Temporal Output
X
GEM-P816 Programming Instructions
OPTION
L
WI995C 2/04
PAGE
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
16
16
15
15
16
16
16
16
16
16
15
15
15
15
15
15
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
NAPCO Security Systems

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents